28 research outputs found

    Error of a temperature probe for cancer ablation monitoring caused by respiratory movements: Ex vivo and in vivo analysis

    Get PDF
    Hyperthermal techniques are spreading as an alternative to conventional surgery for cancer removal. A real-time temperature feedback can be used to adjust the treatment settings, in order to improve the clinical outcomes. In this paper, we experimentally assessed the feasibility for distributed temperature monitoring of a custom probe, which consists of a needle embedding six fiber Bragg gratings (FBGs)

    Acute ischemic stroke with cervical internal carotid artery steno-occlusive lesion: multicenter analysis of endovascular approaches

    Get PDF
    open14noBackground Occlusions of internal carotid artery (ICA), whether isolated or in tandem lesions (TL) have a poor response to treatment with intravenous thrombolysis. Previous studies ​​have demonstrated the superiority of mechanical thrombectomy in the treatment of acute ischemic stroke (AIS) following large vessel occlusion, compared to standard intravenous fibrinolysis. The aim of our study was to describe endovascular treatment (EVT) in AIS due to ICA occlusion, whether isolated or in TL. Methods we assessed the association between 90-day outcome and clinical, demographic, imaging and procedure data in 51 consecutive patients with acute isolated ICA or TL occlusion who underwent endovascular treatment (EVT). We evaluated baseline NIHSS and mRS, ASPECTS, type of occlusion, stent placement, use of stent retrievers and/or thromboaspiration, duration of the procedure, mTICI, procedural therapy and complications. Results A favorable 90-day outcome (mRS 0–2) was achieved in 34 patients (67%) and was significantly associated with the use of dual antiplatelet therapy after the procedure (p = 0.008), shorter procedure duration (p = 0.031), TICI 2b-3 (p < 0.001) and lack of post-procedural hemorrhagic transformation (p = 0.001). Four patients did not survive, resulting in a mortality rate of 8% Conclusions EVT in the treatment of AIS due to ICA occlusion is safe and effective; mortality rates are in agreement with the current literature. The use of the stent is safe and promotes good angiographic results, as well as therapy with a GpIIb / IIIa inhibitor immediately after stent release which is also associated with better 3-month outcome and good revascularization.openLuigi Cirillo, Daniele Giuseppe Romano, Gianfranco Vornetti, Giulia Frauenfelder, Chiara Tamburrano, Francesco Taglialatela, Salvatore Isceri, Renato Saponiero, Rosa Napoletano, Mauro Gentile, Michele Romoli, Ciro Princiotta, Luigi Simonetti, Andrea ZiniLuigi Cirillo, Daniele Giuseppe Romano, Gianfranco Vornetti, Giulia Frauenfelder, Chiara Tamburrano, Francesco Taglialatela, Salvatore Isceri, Renato Saponiero, Rosa Napoletano, Mauro Gentile, Michele Romoli, Ciro Princiotta, Luigi Simonetti, Andrea Zin

    Comparison of temporal evolution of computed tomography imaging features in COVID-19 and influenza infections in a multicenter cohort study

    Full text link
    Purpose To compare temporal evolution of imaging features of coronavirus disease 2019 (COVID-19) and influenza in computed tomography and evaluate their predictive value for distinction. Methods In this retrospective, multicenter study 179 CT examinations of 52 COVID-19 and 44 influenza critically ill patients were included. Lung involvement, main pattern (ground glass opacity, crazy paving, consolidation) and additional lung and chest findings were evaluated by two independent observers. Additional findings and clinical data were compared patient-wise. A decision tree analysis was performed to identify imaging features with predictive value in distinguishing both entities. Results In contrast to influenza patients, lung involvement remains high in COVID-19 patients > 14 days after the diagnosis. The predominant pattern in COVID-19 evolves from ground glass at the beginning to consolidation in later disease. In influenza there is more consolidation at the beginning and overall less ground glass opacity (p = 0.002). Decision tree analysis yielded the following: Earlier in disease course, pleural effusion is a typical feature of influenza (p = 0.007) whereas ground glass opacities indicate COVID-19 (p = 0.04). In later disease, particularly more lung involvement (p < 0.001), but also less pleural (p = 0.005) and pericardial (p = 0.003) effusion favor COVID-19 over influenza. Regardless of time point, less lung involvement (p < 0.001), tree-in-bud (p = 0.002) and pericardial effusion (p = 0.01) make influenza more likely than COVID-19. Conclusions This study identified differences in temporal evolution of imaging features between COVID-19 and influenza. These findings may help to distinguish both diseases in critically ill patients when laboratory findings are delayed or inconclusive

    Modeling Signal Propagation Mechanisms and Ligand-Based Conformational Dynamics of the Hsp90 Molecular Chaperone Full-Length Dimer

    Get PDF
    Hsp90 is a molecular chaperone essential for protein folding and activation in normal homeostasis and stress response. ATP binding and hydrolysis facilitate Hsp90 conformational changes required for client activation. Hsp90 plays an important role in disease states, particularly in cancer, where chaperoning of the mutated and overexpressed oncoproteins is important for function. Recent studies have illuminated mechanisms related to the chaperone function. However, an atomic resolution view of Hsp90 conformational dynamics, determined by the presence of different binding partners, is critical to define communication pathways between remote residues in different domains intimately affecting the chaperone cycle. Here, we present a computational analysis of signal propagation and long-range communication pathways in Hsp90. We carried out molecular dynamics simulations of the full-length Hsp90 dimer, combined with essential dynamics, correlation analysis, and a signal propagation model. All-atom MD simulations with timescales of 70 ns have been performed for complexes with the natural substrates ATP and ADP and for the unliganded dimer. We elucidate the mechanisms of signal propagation and determine “hot spots” involved in interdomain communication pathways from the nucleotide-binding site to the C-terminal domain interface. A comprehensive computational analysis of the Hsp90 communication pathways and dynamics at atomic resolution has revealed the role of the nucleotide in effecting conformational changes, elucidating the mechanisms of signal propagation. Functionally important residues and secondary structure elements emerge as effective mediators of communication between the nucleotide-binding site and the C-terminal interface. Furthermore, we show that specific interdomain signal propagation pathways may be activated as a function of the ligand. Our results support a “conformational selection model” of the Hsp90 mechanism, whereby the protein may exist in a dynamic equilibrium between different conformational states available on the energy landscape and binding of a specific partner can bias the equilibrium toward functionally relevant complexes

    Technical note and first results on JET 7 thromboaspiration device for T-ICA occlusions

    No full text
    Abstract Background To describe technical features and initial results of a novel large-bore reperfusion catheter as first thromboaspiration approach for endovascular stroke treatment in terminal internal carotid artery (T-ICA) occlusions. Methods All patients treated with A Direct Aspiration first-Pass Technique (ADAPT) using JET 7 “Standard Tip” Penumbra Reperfusion catheter for acute T-ICA occlusion were retrospectively included in the study. Baseline data, puncture to recanalization time, number of attempts, switch to second device/technique rate and successful recanalization rate were assessed. Successful recanalization was defined by a thrombolysis in cerebral infarction (TICI) score ≥ 2b and favorable functional outcome was defined according to modified Rankin scale (score, 0–2). Catheter specifics and thromboaspiration reperfusion technique with JET 7 were reported. Results A total of 21 patients who underwent ADAPT with JET 7 Reperfusion catheter were enrolled for the final analysis. ADAPT was performed as first approach in all cases (100%). First attempt successful recanalization (eTICI ≥2b) was obtained in 90,5% of cases. Mean puncture to recanalization time was 16 minutes. Final successful recanalization was reached in 96.5%. Functional independence at 90 was achieved in 57,1% cases. Symptomatic intracranial hemorrhage occurred in one patient within 24 h. Conclusion The large-bore JET 7 reperfusion catheter could be considered as first-line in patients with acute T-ICA occlusion, allowing rapid recanalization and low rate of rescue therapy with stent retriver. Further series and/or trial evaluation are required to confirm our results
    corecore